Electronics S3000 uni.LED dim. Mini [244000] System 3000 universal LED dimmer Mini Gira System 3000 Merkmale: - Switching and dimming light bulbs, HV halogen lamps, electronic transformers for halogen or LED lights, dimmable inductive transformers for halogen or LED lights, HV LED or compact fluorescent lamps. - Operation via auxiliary units. - Automatic or manual setting of dimming principle according to load (leading or trailing edge). - Display of the selected operating mode using LED. - Switch-on function that preserves the life of the lamp. - Switch-on brightness can be saved permanently. - Switch on with the last brightness set, or a saved switch-on brightness. - Minimum brightness can be set. - Electronic short-circuit protection. - Electronic excess-temperature protection. - Operation with or without a neutral conductor connection. Technische Daten: Rated voltage: AC 230 V, 50/60 Hz Standby: max. 0.3 W Connected load at 25 °C - HV LED lamps (leading edge): typically 3 to 50 W - HV LED lamps (trailing edge): typically 3 to 100 W - Compact fluorescent lamp: typically 3 to 50 W - Light bulbs: 20 to 210 W - HV halogen lamps: 20 to 210 W - Tronic transformers: 20 to 210 W - Electronic transformer with LV LED (leading edge): typically 20 to 50 W - Electronic transformer with LV LED (trailing edge): typically 20 to 100 W - Wound electronic transformer: 20 to 210 VA - Wound transformer with NV-LED: typically 20 to 50 VA Auxiliary units - Non-illuminated mechanical push buttons: unlimited - 2-wire auxiliary insert: unlimited - 3-wire auxiliary insert: 10 Cable length - Auxiliary unit: Max. 100 m - Load: Max. 100 m Installation: in device box pursuant to DIN 49073, in combination with a suitable cover Connection cross section - Single-wire: Max. 4 mm² - Fine-wire without core jacket: Max. 4 mm² - fine-wire with core jacket: Max. 2.5 mm² Ambient temperature: -5 °C to +45 °C Dimensions: Dia. 48, H 19.5 mm Hinweise: - In principle, it is possible to operate the dimmer without connecting the neutral conductor, but some LED and CFLi light sources make the neutral conductor connection necessary to avoid flickering. - Operation without a neutral conductor increases the minimum load for light bulbs, HV halogen lamps, Tronic transformers and wound transformers to 50 W. - Electronic transformers and ballast devices for LED lamps can be operated with the dimming procedure specified by the manufacturer. - The switch-on brightness cannot be saved using a button. - The installation adapter mini housing is used for installation in false ceilings5429 00. - If the ambient temperature is higher than 25 °C, the connected load must be reduced. Fabrikat: Gira Bestell-Nr. 2440 00 Menge: 0 Stk xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx