OneKNX DRA heat.act. 6-g cont. [213900] Heating actuator, 6-gang with controller for Gira One and KNX Heating DRA Merkmale: Function in the Gira One system - Single-room control possible through fixed controller and valve output pairing. - Actuator for switching thermal servos in heating and cooling systems. - The outputs are short-circuit and overload-protected. - Servos with 24 V or 230 V rated voltage can be actuated. - Manual actuation of the outputs. - Heating requirement notification, e.g. on a heat pump in combination with a switching actuator, 1-gang 16 A with binary input, 3-gang (Order no. 5061 00) or switching actuator, 2-gang/blind actuator, 1-gang 16 A with binary input, 3-gang (Order no. 5062 00) Valve outputs - 6 independent electronic valve outputs. - Valve control with the characteristic “de-energised open” or “de-energised closed” can be parameterised for each output. - Protection against jammed valves by means of smart flushing with a duration of 5 minutes and a cycle of 1 week. - Boost function for rapid heating of radiators – devices (electric or water-fed). Room temperature controller - 6 independent controllers for heating and cooling mode, optimised for the respective heating and cooling system: Floor heating (electric or hydronic), radiators (electric or hydronic), floor cooling - Heating control type can be set. Continuous PI control or switching 2-point control. - Operating modes: Comfort, standby, night-time reduction, and frost/heat protection. - Automatic heating/cooling requirement notification: for this, the actuator continuously evaluates the corrected variables of the assigned outputs and informs the Gira One system if there is a heating/cooling requirement at an output or in a heating/cooling circuit. The connected switching actuator closes or opens its relay depending on the heating/cooling requirement notification. This enables burner and boiler controllers, which possess appropriate control inputs, to be controlled in an energy-efficient manner (e.g. switching between the reduction and comfort setpoint in a central condensing boiler or heat pump according to requirement). - Limit value specification for floor temperature. - Manual or automatic window-up detection in the event of a drop in temperature, including specification of the duration of frost protection. - Window contact query and visualisation in the Smart Home App: An opened window will result in the activation of the frost protection heating mode after a 5 minutes has elapsed. - Query regarding a heating/cooling switchover, e.g. via the binary input of a heat pump, to allow the current operating mode (heating or cooling) to be forwarded to the heating controller. Function in the Gira KNX system - Heating actuator with integrated room temperature controller for controlling thermal servos for heating and cooling systems. Valve outputs - 6 independent electronic valve outputs. - Valve output 1 can be used as a template for other valve outputs. - Notification for largest actuator variable is configurable. - Servos with 24 V or 230 V rated voltage can be actuated. - Valve control (open/closed while de-energised) can be configured for each output. - Variable input: "switching - 1 bit" and "continuous - 1 byte". - Valve control: "switching - 1 bit", "continuous - 1 byte PWM" or "continuous - 1 byte variable limit". - Status feedback is configurable. - Failure notification for valve operating voltage is configurable. - Overload and short-circuit notification can be set separately for each valve output. - Heat demand and pump control. Anti-jamming prevents the pump from jamming. - Summer or winter operation can be selected via an object. - Each valve outlet can be locked in a forced position. Different corrected variable values can be parameterised for summer and winter mode. - Cyclical monitoring for variable of each output. - Automatic valve flushing. - Operating hours counter configurable for each output. - Service operation for the maintenance or installation of valve drives. - Manual actuation of the outputs independent of the KNX. - Reactions in the event of bus voltage failure and recovery can be set for each valve output following an ETS programming process. - A range of actively transmitting status messages can be delayed globally after a bus voltage recovery or after anETS programming process. Room temperature controller - 12 independent room temperature controllers. - Room temperature controller 1 can be used as a template for other room temperature controllers. - Operating modes: Comfort, standby, night, and frost/heat protection. - Each operating mode can be assigned its own setpoint values. - Setpoint temperature specification: relative (derived from basic setpoint) or absolute (separate setpoint temperatures for each operating mode). - Automatic transmission and cycle time for corrected variable output can be parameterised. - Presence detection using presence button or presence detector. - Switchover of operating modes according to KNX specification. - Frost/heat protection changeover via window status or temperature drop detection. - Operating modes: “Heating”, “Cooling” and “Heating and Cooling” respectively with or without additional stage. - Various control types can be configured according to the heating or cooling level: PI control (constant or switching PWM) or 2-point control (switching). - Different types of heating and cooling can be set. - Control parameters for PI controller (proportional range, reset time) and 2-point controller (hysteresis) can be set. - Automatic and object-oriented switching between "Heating" and "Cooling". - Variable outputs can be disabled via objects. - Room temperature measurement using up to two external KNX temperature sensors. Measured value generation by external sensors configurable or cyclic monitoring. - The actual and setpoint temperatures can be output to the bus (incl. cyclical) after a parameterisable deviation. - Separate or shared variable output in heating or cooling mode (4-pipe or 2-pipe system). - Variable limitation is possible. - Floor temperature limitation possible in heating mode and cooling mode. - Setpoint temperature limitation possible in cooling mode. - Setpoint temperature increase possible in heating mode. - Boost function for faster heating and cooling. - Scenes: Up to 64 internal scenes can be configured per controller. Incl. scene memory function and extended scene retrieval (toggling scenes). Logic functions - The device has 8 internal logic functions. - Logic gate (AND, OR, exclusive AND, exclusive OR, each with up to 4 inputs). - 1-bit to 1-byte converter with input filter, blocking object and specification of output values. - Blocking element with filter and time functions and blocking object. - Comparator for values with 9 different input data formats and many comparison operations. - Limit value switch with hysteresis with upper and lower threshold value for 9 different input data formats.Incl. specification of the 1-bit output values. - The logic functions have their own KNX communication objects and can process telegrams from the actuator or other bus devices. Technische Daten: Gira One Medium: Twisted pair (TP),YCYM 2 x 2 x 0.8 KNX medium: TP256 Test voltage: 4 kV (KNX/EIB bus line) Outputs: 6 Controller: 6 Contact type: Triac Switching voltage: AC 24/230 V, 50/60 Hz Switching current: 5 to 160 mA Switch-on current: 1.5 A (2 s) max Number of drives per output - AC 230 V drives: 4 - AC 24 V drives: 2 Connection cross section: Max. 4 mm² Ambient temperature: -5 °C to +45 °C Hinweise: - Can be updated via the Gira Project Assistant (GPA). Lieferumfang: - KNX connection and junction terminal included with delivery. Abmessungen: Teilungseinheiten (TE): 4 Fabrikat: Gira Bestell-Nr. 2139 00 DRA Menge: 0 Stk xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx