Door communication DCS btn I/F 2-g [121000]
DCS push button interface, 2-gang
Gira system devices
Merkmale:
- The DCS button interface, 2-gang is used to implement a zero-voltage button
signal on the Gira door communication bus.
- The DCS button interface features two separate inputs for the connection of
zero-voltage buttons.
- The inputs can either be used to trigger a switching action (e.g. switching
lights) via a switching actuator or flush-mounted switching actuator, or they
can be assigned to a home station.
- The DCS button interface is intended for installation in a device box behind
a conventional button.
Technische Daten:
Power supply: DC 26 V ± 2 V (by 2-wire bus)
Ambient temperature: -5 °C to +50 °C
Connections
- 2-wire bus: 2 x plug terminal
Number of inputs: 2
Dimensions
- W x H x D: 43 x 28 x 15 mm
Hinweise:
- The button is connected using a 3-wire, approx. 20 cm long connection
cable. This connection cable can be extended to a maximum of 5 m.
- When the button interface is assigned to a home station, the two inputs
function differently:Input 1triggers a floor call. This input
is required when only a 2-wire line is available to connect a home station
incl. floor-call button (e.g. when retrofitting an existing door
station).Input 2triggers a door call. This input is required
if the automatic door opener for the home station is to be triggered using a
mechanical button.
Fabrikat: Gira
Bestell-Nr. 1210 00
Menge: 0 Stk