OneKNX DRA swit./blind act. 6-g/3-g 16 A Std [502300] Switching actuator, 6-gang 16 A / blind actuator, 3-gang 16 A Standard for Gira One and KNX Switching / blinds Standard DRA Merkmale: Function in the Gira One system - Actuator for switching devices or for controlling blinds, shutters, awnings, skylight operation. - In blind operation, the adjacent outputs (A1/A2, A3/A4...) are combined into one blind output. - Mixed operation at one actuator (e.g. A1 and A2 blind, A3 & A4 blind, A5 switching, A6 switching, etc.) is possible. - Manual actuation of the outputs. - Programming and start-up with the Gira Project Assistant (GPA), from version 5.0. - Encrypted data transfer between the Gira One devices. Shading and ventilation function - Control of slat blinds, shutters, awnings, skylights or roof domes. - Runtimes optionally adjustable. - Sun protection function with curtain or slat positions at the beginning or end of the function that can be set for each output. - Setting of the delay time at the beginning or end of the sunshine. - Fabric stretching for awnings. - In the event of an active wind alarm, e.g. with a conventional weather station with zero-voltage relay outputs for the wind alarm, the blinds raise and are automatically locked. The status of the binary input is monitored on a cyclical basis. - In the event of an active rain alarm, e.g. with a conventional weather station with zero-voltage relay outputs for the rain alarm, the skylights or roof domes close immediately and are automatically locked. The status of the binary input is monitored on a cyclical basis. - In the event of an active frost alarm, e.g. with a conventional weather station with zero-voltage relay outputs for the frost alarm, active travel by shutters is stopped and locked to protect the shutter motor. The status of the binary input is monitored on a cyclical basis. - Door contact query and visualisation in the Smart Home App: An open door results in the raising and locking of the blind or shutter. Switching functions - NO contact or NC contact operation. - Setting of a switch-on or switch-off delay. - Staircase function; a pre-warning time can also be set. - Parameterisation as a switching function for lights or socket outlets, a garage door function or a door opener function, for example. - Garage door function: The time for closing the relay can be parameterised. - Door opener function: The time for closing the relay can be parameterised. Function in the Gira KNX system - Blind or switching operation can be parametrised. In blind operation, the adjacent outputs (A1/A2, A3/A4...) are combined into one blind output. Mixed operation at one actuator (e.g. A1 & A2 blind, A3 & A4 blind, A5 switching, A6 switching ...) is possible. - Actively transmitting feedback or status messages can be delayed globally after a bus voltage recovery or ETS programming operation. - Manual operation of the outputs independently of KNX with intelligent LED status displays for saving energy. - Advanced manual actuation: Toggle between blind mode and switching mode before starting up the ETS. - Heartbeat function for monitoring the device, cyclical transmission 1 bit. - Bistable relay. - Supply from KNX bus, no additional power supply required. - Simplified terminal connection (no terminal overlapping). Blind functions - Operating mode can be parametrised: Control of slat blinds, roller shutters, awnings, skylights or ventilation flaps. - Separately parameterisable curtain runtimes with runtime extension for movements into the upper end position. - For slat blinds, a slat runtime can be parametrised independently. - Switchover time for change of direction and times for short and long-term operation (Step, Move) can be set. - Feedback on the curtain or slat position. In addition, feedback on an invalid curtain position or a drive movement is possible. - Assignments of up to 5 different safety functions (3 wind alarms, 1 rain alarm, 1 frost alarm), or with cyclical monitoring. The safety functions (objects, cycle times, priority) are created in a device-based manner for all outputs. An assignment of individual outputs to the safety functions and the safety reactions can be parametrised based on the channel. - Blocking function can be implemented for each blind output. - Simple sun protection: Sun protection function with fixed and variable curtain or slat positions at the beginning or end of the function can be activated separately for each output. - Up to 16 internal scenes can be parametrised per output. - Scene memory function: Additional visual feedback. - Twilight function. - Status messages for upper and lower end positions. Switching functions - Independent switching of the switching outputs. - NO contact or NC contact operation. - Switching feedback: transmitting to the bus cyclically or when there is a change. - Logical individual linking function for each output. - Reaction upon bus voltage recovery can be set for each output (ON or no reaction). - Blocking function with feedback object can be parametrised for each channel. - Time functions (switch-on and switch-off delay, staircase light function – also with advance warning function). - Integration into light scenes possible: Up to 16 internal scenes can be parametrised per output. Technische Daten: Gira One Medium: Twisted pair YCYM 2 x 2 x 0.8 KNX medium: TP256 Test voltage: 4 kV (KNX/EIB bus line) Rated voltage - KNX: DC 21 to 32 V SELV Switching capacity: AC 250 V, 16 A / AC1 Maximum switch-on current: 800 A (200 µs), 165 A (20 ms) Current carrying capacity of adjacent outputs: Total 20 A Connected load - Ohmic load: 3000 W - Capacitive load: 16 A, max. 140 µF - Motors (blind or fan): 1380 W - Light bulbs: 2300 W - HV halogen lamps: 2500 W - HV LED lamps: typically 400 W - Wound electronic transformer: 1200 VA - Tronic transformer: 1500 W - Fluorescent lamps, uncompensated: 1000 VA - Fluorescent lamps,lead-lag circuit: 2300 VA - Fluorescent lamps, parallel-compensated: 1160 VA - Mercury-vapour lamps, uncompensated: 1000 W - Mercury-vapour lamps, parallel-compensated: 1160 W Connections - Gira One Bus: Connection and junction terminal - KNX: Connection and junction terminal - Load: Screw terminals (max. 4 mm² or 2 x 2.5 mm²) Current consumption - Gira One Bus: 5 to 25 mA Hinweise: - KNX Data Secure compatible. - Fast application download (long frame support). - Firmware can be updated using the Gira ETS Service App (additional software). - Can be updated via the Gira Project Assistant (GPA) - Installation on DIN top-hat rail. Lieferumfang: - KNX connection and junction terminal included with delivery. Abmessungen: Teilungseinheiten (TE): 4 Fabrikat: Gira Bestell-Nr. 5023 00 DRA Menge: 0 Stk Einzelpreis: 255.76 Euro (o. MwSt.) xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx